Parker PRT series 0.1s to 30s Pneumatic Timer, 8 bar max

RS Stok Numarası: 410-517Marka: ParkerÜretici Parça Numarası: PRT-A10
brand-logo

Teknik Belgeler

Özellikler

Marka

Parker

Maksimum Süre

30s

Minimum Süre

0.1s

Maksimum Çalışma Sıcaklığı

+60°C

Üretici Serisi

PRT

Minimum Çalışma Basıncı

3bar

Maksimum Çalışma Basıncı

8 bar

Minimum Çalışma Sıcaklığı

-15°C

Ürün Ayrıntıları

Timer Module

A pneumatic timer consists of a solenoid coil/core, operating spring, timing disk, filter and diaphragm. The core moves up into the coil when it has been energized and this leads to pressure on the diaphragm. The diaphragm moves into the top chamber which un-traps the air through the timing disk. By altering the needle valve you can adjust the amount of delay.

Logic Systems

Logic units are best thought of as miniature valves, whose purpose is to influence the behaviour of larger power valves. They achieve this by producing and receiving output and input signals, using the common air supply. In this way, they are able to monitor and control a whole sequence of operations with great accuracy and repeatability.

İlginizi çekebilir

Stok bilgileri geçici olarak kullanılamıyor.

Ayrıntılı bilgi için iletşime geçiniz

Stok bilgileri geçici olarak kullanılamıyor.

Teklif İsteyiniz

Parker PRT series 0.1s to 30s Pneumatic Timer, 8 bar max
sticker-359

Teklif İsteyiniz

Parker PRT series 0.1s to 30s Pneumatic Timer, 8 bar max
Stok bilgileri geçici olarak kullanılamıyor.
sticker-359
İlginizi çekebilir

Teknik Belgeler

Özellikler

Marka

Parker

Maksimum Süre

30s

Minimum Süre

0.1s

Maksimum Çalışma Sıcaklığı

+60°C

Üretici Serisi

PRT

Minimum Çalışma Basıncı

3bar

Maksimum Çalışma Basıncı

8 bar

Minimum Çalışma Sıcaklığı

-15°C

Ürün Ayrıntıları

Timer Module

A pneumatic timer consists of a solenoid coil/core, operating spring, timing disk, filter and diaphragm. The core moves up into the coil when it has been energized and this leads to pressure on the diaphragm. The diaphragm moves into the top chamber which un-traps the air through the timing disk. By altering the needle valve you can adjust the amount of delay.

Logic Systems

Logic units are best thought of as miniature valves, whose purpose is to influence the behaviour of larger power valves. They achieve this by producing and receiving output and input signals, using the common air supply. In this way, they are able to monitor and control a whole sequence of operations with great accuracy and repeatability.