Teknik Belgeler
Özellikler
Aralık
SmartGuard 600
I/O Sayısı
24
Güvenlik Girişlerinin Sayısı
16
Güvenlik Çıkışlarının Sayısı
8
Güvenlik Kategorisi
4
SIL
SIL 3
Besleme Gerilimi
24 V dc
Kontak Akımı Değeri
500 mA
Genişlik
90.4mm
Uzunluk
99mm
Derinlik
131.4mm
Boyutlar
99 x 90,4 x 131,4 mm
Ürün Ayrıntıları
Smartguard 600, Safety Controller, Base Unit
Designed for applications that have traditionally fallen between safety relays and safety PLCs, the SmartGuard 600 is a general purpose programmable safety controller for safety applications that require some complex logic - allowing for more advanced safety functionality. It features 16 safety-rated inputs, 8 safety-rated outputs, 4 pulse test sources, and a DeviceNet connection that supports both standard and CIP Safety communication. Configuration and programming is accomplished through the built-in USB port.
Approvals
c-UL-us, UL listed for Class 1 Division 2 Groups A, B, C, D Hazardous Locations; UL certified for Functional Safety. See UL File E256621; CE; C-Tick; TUV certified for functional safety up to SIL 3, Cat. 4; ODVA conformance tested to DeviceNet and DeviceNet Safety specifications
Standards
IEC61508 SIL3 and EN954-1 Cat.4
Teklif İsteyiniz
1
Teklif İsteyiniz
1
Stok bilgileri geçici olarak kullanılamıyor.
Ayrıntılı bilgi için iletşime geçiniz
Teknik Belgeler
Özellikler
Aralık
SmartGuard 600
I/O Sayısı
24
Güvenlik Girişlerinin Sayısı
16
Güvenlik Çıkışlarının Sayısı
8
Güvenlik Kategorisi
4
SIL
SIL 3
Besleme Gerilimi
24 V dc
Kontak Akımı Değeri
500 mA
Genişlik
90.4mm
Uzunluk
99mm
Derinlik
131.4mm
Boyutlar
99 x 90,4 x 131,4 mm
Ürün Ayrıntıları
Smartguard 600, Safety Controller, Base Unit
Designed for applications that have traditionally fallen between safety relays and safety PLCs, the SmartGuard 600 is a general purpose programmable safety controller for safety applications that require some complex logic - allowing for more advanced safety functionality. It features 16 safety-rated inputs, 8 safety-rated outputs, 4 pulse test sources, and a DeviceNet connection that supports both standard and CIP Safety communication. Configuration and programming is accomplished through the built-in USB port.
Approvals
c-UL-us, UL listed for Class 1 Division 2 Groups A, B, C, D Hazardous Locations; UL certified for Functional Safety. See UL File E256621; CE; C-Tick; TUV certified for functional safety up to SIL 3, Cat. 4; ODVA conformance tested to DeviceNet and DeviceNet Safety specifications
Standards
IEC61508 SIL3 and EN954-1 Cat.4