Teknik Belgeler
Özellikler
Marka
LittelfuseSigorta Boyutu
6.3 x 32mm
Akım Değeri
16A
Gerilim Değeri
250V
Kontak Malzemesi
Bakır Alaşım
Başlık Stili
Kanallı
Seri
800
Uyumlu Sigorta Çapı
6.3mm
Uluslararası Koruma Derecesi
IP40
Koruma Kategorisi
PC2
Uyumlu Sigorta Uzunluğu
32mm
Menşe
Czech Republic
Ürün Ayrıntıları
'WICKMANN' Shocksafe, Panel mount
One complete fuse holder body system requires one holder body and one cap of the appropriate size.,Maximum current 10A @ 250V (6·3x32mm), 6·3A @ 250V (5x20mm)
Approvals
VDE, SEMKO, UL, CSA
Panel Mounting
CATEGORIES OF PROTECTION AGAINST ELECTRIC SHOCK,PC1: No integral protection against electric shock. If required, designers must provide additional protection against electric shock on equipment.,PC2: With integral protection against electric shock. Fuse-holders shall have live parts inaccessible to IEC529 standard test finger, when fully assembled, without fuse carrier or fuse in place and when fuse carrier, with fuse is being inserted or withdrawn.,PC3: With integral protection against electric shock. Fuse-holders shall have live parts inaccessible to IEC529 1mm diameter rigid test wire when fully assembled, without fuse carrier or fuse in place and when fuse carrier, with fuse is being inserted or withdrawn.
Stok bilgileri geçici olarak kullanılamıyor.
Ayrıntılı bilgi için iletşime geçiniz
P.O.A.
5
P.O.A.
5
Teknik Belgeler
Özellikler
Marka
LittelfuseSigorta Boyutu
6.3 x 32mm
Akım Değeri
16A
Gerilim Değeri
250V
Kontak Malzemesi
Bakır Alaşım
Başlık Stili
Kanallı
Seri
800
Uyumlu Sigorta Çapı
6.3mm
Uluslararası Koruma Derecesi
IP40
Koruma Kategorisi
PC2
Uyumlu Sigorta Uzunluğu
32mm
Menşe
Czech Republic
Ürün Ayrıntıları
'WICKMANN' Shocksafe, Panel mount
One complete fuse holder body system requires one holder body and one cap of the appropriate size.,Maximum current 10A @ 250V (6·3x32mm), 6·3A @ 250V (5x20mm)
Approvals
VDE, SEMKO, UL, CSA
Panel Mounting
CATEGORIES OF PROTECTION AGAINST ELECTRIC SHOCK,PC1: No integral protection against electric shock. If required, designers must provide additional protection against electric shock on equipment.,PC2: With integral protection against electric shock. Fuse-holders shall have live parts inaccessible to IEC529 standard test finger, when fully assembled, without fuse carrier or fuse in place and when fuse carrier, with fuse is being inserted or withdrawn.,PC3: With integral protection against electric shock. Fuse-holders shall have live parts inaccessible to IEC529 1mm diameter rigid test wire when fully assembled, without fuse carrier or fuse in place and when fuse carrier, with fuse is being inserted or withdrawn.