PD Devices Şebeke Parafudr, 400 V, 10kA, Duvara Monte, 6651C Serisi

RS Stok Numarası: 206-7465Marka: PD DevicesÜretici Parça Numarası: RS-6651C/3
brand-logo

Teknik Belgeler

Özellikler

Bastırıcı Tipi

Şebeke Koruyucu

Maksimum Gerilim Değeri

400 V

Montaj Tipi

Duvara Monte

Maksimum Ani Akım

10kA

Seri

6651C

Uzunluk

182mm

Derinlik

81mm

Yükseklik

61mm

Boyutlar

182 x 81 x 61mm

Minimum Çalışma Sıcaklığı

-40°C

Maksimum Çalışma Sıcaklığı

+70°C

Menşe

United Kingdom

Ürün Ayrıntıları

Transient Voltage Suppressors (Modules,Industrial)

Voltage surges, often referred to as spikes or transient overvoltages are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage surges are usually caused by lightning activity and can reach up to 6000V, with current surges of up to 3000A. The maximum size of the voltage and current surges depends on the location within the buildings wiring system. BS6651:1999 Annex C which was replaced in August 2008 by BS EN 62305-4:2006 is complemented by BS EN 61643-11/12 and covers location categories and provides guidance on protection of electronic equipment. For mains power systems, Types I, II and III are used. Surge protection devices not designed to fit into these categories may only provide limited protection and the equipment they protect may suffer damage.

İlginizi çekebilir

Stok bilgileri geçici olarak kullanılamıyor.

Ayrıntılı bilgi için iletşime geçiniz

Stok bilgileri geçici olarak kullanılamıyor.

P.O.A.

PD Devices Şebeke Parafudr, 400 V, 10kA, Duvara Monte, 6651C Serisi
sticker-359

P.O.A.

PD Devices Şebeke Parafudr, 400 V, 10kA, Duvara Monte, 6651C Serisi
Stok bilgileri geçici olarak kullanılamıyor.
sticker-359
İlginizi çekebilir

Teknik Belgeler

Özellikler

Bastırıcı Tipi

Şebeke Koruyucu

Maksimum Gerilim Değeri

400 V

Montaj Tipi

Duvara Monte

Maksimum Ani Akım

10kA

Seri

6651C

Uzunluk

182mm

Derinlik

81mm

Yükseklik

61mm

Boyutlar

182 x 81 x 61mm

Minimum Çalışma Sıcaklığı

-40°C

Maksimum Çalışma Sıcaklığı

+70°C

Menşe

United Kingdom

Ürün Ayrıntıları

Transient Voltage Suppressors (Modules,Industrial)

Voltage surges, often referred to as spikes or transient overvoltages are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage surges are usually caused by lightning activity and can reach up to 6000V, with current surges of up to 3000A. The maximum size of the voltage and current surges depends on the location within the buildings wiring system. BS6651:1999 Annex C which was replaced in August 2008 by BS EN 62305-4:2006 is complemented by BS EN 61643-11/12 and covers location categories and provides guidance on protection of electronic equipment. For mains power systems, Types I, II and III are used. Surge protection devices not designed to fit into these categories may only provide limited protection and the equipment they protect may suffer damage.

İlginizi çekebilir