Teknik Belgeler
Özellikler
Aralık
SmartGuard 600
I/O Sayısı
24
Güvenlik Girişlerinin Sayısı
16
Güvenlik Çıkışlarının Sayısı
8
Güvenlik Kategorisi
4
SIL
SIL 3
Besleme Gerilimi
24 V dc
Kontak Akımı Değeri
500 mA
Boyutlar
99 x 90,4 x 131,4 mm
Derinlik
131.4mm
Uzunluk
99mm
Genişlik
90.4mm
Ürün Ayrıntıları
Smartguard 600, Safety Controller, Base Unit
Designed for applications that have traditionally fallen between safety relays and safety PLCs, the SmartGuard 600 is a general purpose programmable safety controller for safety applications that require some complex logic - allowing for more advanced safety functionality. It features 16 safety-rated inputs, 8 safety-rated outputs, 4 pulse test sources, and a DeviceNet connection that supports both standard and CIP Safety communication. Configuration and programming is accomplished through the built-in USB port.
Approvals
c-UL-us, UL listed for Class 1 Division 2 Groups A, B, C, D Hazardous Locations; UL certified for Functional Safety. See UL File E256621; CE; C-Tick; TUV certified for functional safety up to SIL 3, Cat. 4; ODVA conformance tested to DeviceNet and DeviceNet Safety specifications
Standards
IEC61508 SIL3 and EN954-1 Cat.4
Stok bilgileri geçici olarak kullanılamıyor.
Ayrıntılı bilgi için iletşime geçiniz
Teklif İsteyiniz
1
Teklif İsteyiniz
1
Teknik Belgeler
Özellikler
Aralık
SmartGuard 600
I/O Sayısı
24
Güvenlik Girişlerinin Sayısı
16
Güvenlik Çıkışlarının Sayısı
8
Güvenlik Kategorisi
4
SIL
SIL 3
Besleme Gerilimi
24 V dc
Kontak Akımı Değeri
500 mA
Boyutlar
99 x 90,4 x 131,4 mm
Derinlik
131.4mm
Uzunluk
99mm
Genişlik
90.4mm
Ürün Ayrıntıları
Smartguard 600, Safety Controller, Base Unit
Designed for applications that have traditionally fallen between safety relays and safety PLCs, the SmartGuard 600 is a general purpose programmable safety controller for safety applications that require some complex logic - allowing for more advanced safety functionality. It features 16 safety-rated inputs, 8 safety-rated outputs, 4 pulse test sources, and a DeviceNet connection that supports both standard and CIP Safety communication. Configuration and programming is accomplished through the built-in USB port.
Approvals
c-UL-us, UL listed for Class 1 Division 2 Groups A, B, C, D Hazardous Locations; UL certified for Functional Safety. See UL File E256621; CE; C-Tick; TUV certified for functional safety up to SIL 3, Cat. 4; ODVA conformance tested to DeviceNet and DeviceNet Safety specifications
Standards
IEC61508 SIL3 and EN954-1 Cat.4