Bourns 2 Kutuplu Parafudr, 65 V dc, 30kA, 1320 Serisi

RS Stok Numarası: 172-8706Marka: BournsÜretici Parça Numarası: 1320-S-48
brand-logo

Teknik Belgeler

Özellikler

Marka

Bourns

Bastırıcı Tipi

2 Kutuplu Koruyucu

Maksimum Gerilim Değeri

65 V dc

Montaj Tipi

DIN Rayı

Maksimum Ani Akım

30kA

Seri

1320

Uzunluk

18mm

Derinlik

67mm

Yükseklik

90mm

Boyutlar

18 x 67 x 90mm

Minimum Çalışma Sıcaklığı

-40°C

Maksimum Çalışma Sıcaklığı

+85°C

Menşe

China

Ürün Ayrıntıları

Bourns DC Surge Protection Devices

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.

Stok bilgileri geçici olarak kullanılamıyor.

Ayrıntılı bilgi için iletşime geçiniz

Stok bilgileri geçici olarak kullanılamıyor.

4.177,046 TL

Each (In a Box of 8) KDV Hariç

5.012,455 TL

Each (In a Box of 8) KDV Dahil

Bourns 2 Kutuplu Parafudr, 65 V dc, 30kA, 1320 Serisi

4.177,046 TL

Each (In a Box of 8) KDV Hariç

5.012,455 TL

Each (In a Box of 8) KDV Dahil

Bourns 2 Kutuplu Parafudr, 65 V dc, 30kA, 1320 Serisi
Stok bilgileri geçici olarak kullanılamıyor.

Teknik Belgeler

Özellikler

Marka

Bourns

Bastırıcı Tipi

2 Kutuplu Koruyucu

Maksimum Gerilim Değeri

65 V dc

Montaj Tipi

DIN Rayı

Maksimum Ani Akım

30kA

Seri

1320

Uzunluk

18mm

Derinlik

67mm

Yükseklik

90mm

Boyutlar

18 x 67 x 90mm

Minimum Çalışma Sıcaklığı

-40°C

Maksimum Çalışma Sıcaklığı

+85°C

Menşe

China

Ürün Ayrıntıları

Bourns DC Surge Protection Devices

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.