Teknik Belgeler
Özellikler
Marka
DehnBastırıcı Tipi
Tip 2 Durdurucu
Maksimum Gerilim Değeri
23 V ac, 33 V dc
Montaj Tipi
DIN Rayı
Maksimum Ani Akım
20kA
Seri
DCO
Uzunluk
6mm
Derinlik
87.5mm
Yükseklik
94.5mm
Boyutlar
6 x 87.5 x 94.5mm
Minimum Çalışma Sıcaklığı
-40°C
Maksimum Çalışma Sıcaklığı
+80°C
Menşe
Germany
Ürün Ayrıntıları
Dehn Slim Terminal Block Surge Arresters
Energy coordinated two-stage arrester with disconnection function for protecting two single lines sharing a common reference potential as well as unbalanced interfaces
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.
Stok bilgileri geçici olarak kullanılamıyor.
Ayrıntılı bilgi için iletşime geçiniz
4.748,79 TL
4.748,79 TL Each (KDV Hariç)
5.698,55 TL
5.698,55 TL Each KDV Dahil
1
4.748,79 TL
4.748,79 TL Each (KDV Hariç)
5.698,55 TL
5.698,55 TL Each KDV Dahil
1
Toptan Satın Al
Miktar | Birim Fiyat |
---|---|
1 - 4 | 4.748,79 TL |
5 - 9 | 4.559,38 TL |
10 - 19 | 4.322,50 TL |
20 - 29 | 3.943,21 TL |
30+ | 3.515,98 TL |
Teknik Belgeler
Özellikler
Marka
DehnBastırıcı Tipi
Tip 2 Durdurucu
Maksimum Gerilim Değeri
23 V ac, 33 V dc
Montaj Tipi
DIN Rayı
Maksimum Ani Akım
20kA
Seri
DCO
Uzunluk
6mm
Derinlik
87.5mm
Yükseklik
94.5mm
Boyutlar
6 x 87.5 x 94.5mm
Minimum Çalışma Sıcaklığı
-40°C
Maksimum Çalışma Sıcaklığı
+80°C
Menşe
Germany
Ürün Ayrıntıları
Dehn Slim Terminal Block Surge Arresters
Energy coordinated two-stage arrester with disconnection function for protecting two single lines sharing a common reference potential as well as unbalanced interfaces
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.