Teknik Belgeler
Özellikler
Marka
DehnBastırıcı Tipi
Ani Artış Durdurucu Koruma Modülü
Maksimum Gerilim Değeri
275 V ac, 350 V dc
Montaj Tipi
Takılabilir
Maksimum Ani Akım
40kA
Seri
DG
Uzunluk
45mm
Derinlik
18mm
Yükseklik
51mm
Boyutlar
45 x 18 x 51mm
Menşe
Germany
Ürün Ayrıntıları
DEHNguard and DEHNrail Replacement Plugin Modules
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.
Stok bilgileri geçici olarak kullanılamıyor.
Ayrıntılı bilgi için iletşime geçiniz
4.189,49 TL
4.189,49 TL Each (KDV Hariç)
5.027,39 TL
5.027,39 TL Each KDV Dahil
1
![sticker-359](https://cms.rsdelivers.com/repository-v1/yeniiyifiyat.gif)
4.189,49 TL
4.189,49 TL Each (KDV Hariç)
5.027,39 TL
5.027,39 TL Each KDV Dahil
1
![sticker-359](https://cms.rsdelivers.com/repository-v1/yeniiyifiyat.gif)
Toptan Satın Al
Miktar | Birim Fiyat |
---|---|
1 - 4 | 4.189,49 TL |
5 - 9 | 4.022,17 TL |
10 - 24 | 3.813,49 TL |
25+ | 3.479,32 TL |
Teknik Belgeler
Özellikler
Marka
DehnBastırıcı Tipi
Ani Artış Durdurucu Koruma Modülü
Maksimum Gerilim Değeri
275 V ac, 350 V dc
Montaj Tipi
Takılabilir
Maksimum Ani Akım
40kA
Seri
DG
Uzunluk
45mm
Derinlik
18mm
Yükseklik
51mm
Boyutlar
45 x 18 x 51mm
Menşe
Germany
Ürün Ayrıntıları
DEHNguard and DEHNrail Replacement Plugin Modules
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.