Teknik Belgeler
Özellikler
Marka
DehnBastırıcı Tipi
Şebeke Koruyucu
Maksimum Gerilim Değeri
280 V ac
Montaj Tipi
Açık Delik
Maksimum Ani Akım
5kA
Seri
VC
Uzunluk
24mm
Derinlik
15mm
Yükseklik
32mm
Boyutlar
24 x 15 x 32mm
Kablo Hatvesi
5mm
Minimum Çalışma Sıcaklığı
-25°C
Maksimum Çalışma Sıcaklığı
+40°C
Menşe
Germany
Ürün Ayrıntıları
Dehn PCB Mounting Surge Arresters
Mains module with surge protection and floating break contact for installation into terminal equipment to be protected
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.
2.974,82 TL
2.974,82 TL Each (KDV Hariç)
3.569,78 TL
3.569,78 TL Each KDV Dahil
1
2.974,82 TL
2.974,82 TL Each (KDV Hariç)
3.569,78 TL
3.569,78 TL Each KDV Dahil
Stok bilgileri geçici olarak kullanılamıyor.
1
Stok bilgileri geçici olarak kullanılamıyor.
| Miktar | Birim Fiyat |
|---|---|
| 1 - 4 | 2.974,82 TL |
| 5 - 9 | 2.855,92 TL |
| 10 - 24 | 2.707,44 TL |
| 25 - 49 | 2.470,22 TL |
| 50+ | 2.202,84 TL |
Teknik Belgeler
Özellikler
Marka
DehnBastırıcı Tipi
Şebeke Koruyucu
Maksimum Gerilim Değeri
280 V ac
Montaj Tipi
Açık Delik
Maksimum Ani Akım
5kA
Seri
VC
Uzunluk
24mm
Derinlik
15mm
Yükseklik
32mm
Boyutlar
24 x 15 x 32mm
Kablo Hatvesi
5mm
Minimum Çalışma Sıcaklığı
-25°C
Maksimum Çalışma Sıcaklığı
+40°C
Menşe
Germany
Ürün Ayrıntıları
Dehn PCB Mounting Surge Arresters
Mains module with surge protection and floating break contact for installation into terminal equipment to be protected
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.