Teknik Belgeler
Özellikler
Marka
FigaroAlgılanan Gazlar
CFC
Ürün Tipi
Gaz Sensörü
Alt Tip
Gas Sensor
Minimum Besleme Gerilimi
0.2V
Maksimum Besleme Gerilimi
24V
Pim Sayısı
6
Paket Tipi
Modül
Maksimum Çalışma Sıcaklığı
65°C
Standartlar/Onaylar
No
Seri
TGS 832-A00
Genişlik
19.5 mm
Uzunluk
23mm
Yükseklik
19.5mm
Ağırlık
2.4g
Otomotiv Standardı
NO
Ürün Ayrıntıları
TGS832 Chlorofluorocarbon (CFC) Gas Sensors
Gas sensors from Figaro for the detection of Chlorofluorocarbon (CFC) or Halocarbon gases. These devices utilise tin dioxide (SnO2) semiconductor technology to provide an output proportion to gas concentration. The sensors have high sensitivity to the refrigerant gases commonly used in air conditioning systems and refrigerators, such as R-134a, R-404a, R-407c and R-410.
PCB Mounted Gas Sensors
Operating conditions in which Sensors are used will vary with each customer's application. Gas and oxygen sensors are not authorised for use as critical components in life support applications wherein a failure or malfunction of the products may result in injury or threat to life. Non-calibrated PCB gas sensors will not operate properly if not calibrated prior to usage.
Stok bilgileri geçici olarak kullanılamıyor.
2.036,70 TL
2.036,70 TL Each (KDV Hariç)
2.444,04 TL
2.444,04 TL Each KDV Dahil
1
2.036,70 TL
2.036,70 TL Each (KDV Hariç)
2.444,04 TL
2.444,04 TL Each KDV Dahil
Stok bilgileri geçici olarak kullanılamıyor.
1
| Miktar | Birim Fiyat |
|---|---|
| 1 - 4 | 2.036,70 TL |
| 5+ | 1.900,92 TL |
Teknik Belgeler
Özellikler
Marka
FigaroAlgılanan Gazlar
CFC
Ürün Tipi
Gaz Sensörü
Alt Tip
Gas Sensor
Minimum Besleme Gerilimi
0.2V
Maksimum Besleme Gerilimi
24V
Pim Sayısı
6
Paket Tipi
Modül
Maksimum Çalışma Sıcaklığı
65°C
Standartlar/Onaylar
No
Seri
TGS 832-A00
Genişlik
19.5 mm
Uzunluk
23mm
Yükseklik
19.5mm
Ağırlık
2.4g
Otomotiv Standardı
NO
Ürün Ayrıntıları
TGS832 Chlorofluorocarbon (CFC) Gas Sensors
Gas sensors from Figaro for the detection of Chlorofluorocarbon (CFC) or Halocarbon gases. These devices utilise tin dioxide (SnO2) semiconductor technology to provide an output proportion to gas concentration. The sensors have high sensitivity to the refrigerant gases commonly used in air conditioning systems and refrigerators, such as R-134a, R-404a, R-407c and R-410.
PCB Mounted Gas Sensors
Operating conditions in which Sensors are used will vary with each customer's application. Gas and oxygen sensors are not authorised for use as critical components in life support applications wherein a failure or malfunction of the products may result in injury or threat to life. Non-calibrated PCB gas sensors will not operate properly if not calibrated prior to usage.