Interface Module, Cable Mount, Female, 16 Pole, 500 V, 16A
Teknik Belgeler
Özellikler
Marka
HartingCinsiyet
Dişi
Tel Boyutu
24 → 14 AWG
Kontakların Sayısı
16
Montaj Tipi
Kablo Montajı
Gerilim Değeri
500 V
Akım Değeri
16A
Derinlik
34mm
Maksimum Çalışma Sıcaklığı
+125°C
Minimum Çalışma Sıcaklığı
-40°C
CAD Drawing
3D CAD Model
Ürün Ayrıntıları
Han E® AV Terminal Blocks
From Han E, these AV terminal blocks are used in conjunction with the bulkhead/panel mount housing to allow a terminal block style wire termination inside the equipment, perfect for customizable connection solutions.
Warning
These connectors should not be mated or unmated under electrical load. Connectors of the same or different types arranged in a line should be polarised to prevent the possibility of wrong connection.
Approvals
UL, CSA, SEV
Han E® AV 16A Terminal Blocks
These Han E® AV inserts are rated at 16A. They are intended for use with hoods and housings contained within ranges 5, 6, 7, & 8. These housing ranges are associated to a specific Harting 'Size' number identifier. See the 'compatibility' table for details of this relationship, and stock numbers of housings that are typical of each range.
Stok bilgileri geçici olarak kullanılamıyor.
Ayrıntılı bilgi için iletşime geçiniz
Teklif İsteyiniz
1
![sticker-359](https://cms.rsdelivers.com/repository-v1/yeniiyifiyat.gif)
Teklif İsteyiniz
1
![sticker-359](https://cms.rsdelivers.com/repository-v1/yeniiyifiyat.gif)
Teknik Belgeler
Özellikler
Marka
HartingCinsiyet
Dişi
Tel Boyutu
24 → 14 AWG
Kontakların Sayısı
16
Montaj Tipi
Kablo Montajı
Gerilim Değeri
500 V
Akım Değeri
16A
Derinlik
34mm
Maksimum Çalışma Sıcaklığı
+125°C
Minimum Çalışma Sıcaklığı
-40°C
CAD Drawing
3D CAD Model
Ürün Ayrıntıları
Han E® AV Terminal Blocks
From Han E, these AV terminal blocks are used in conjunction with the bulkhead/panel mount housing to allow a terminal block style wire termination inside the equipment, perfect for customizable connection solutions.
Warning
These connectors should not be mated or unmated under electrical load. Connectors of the same or different types arranged in a line should be polarised to prevent the possibility of wrong connection.
Approvals
UL, CSA, SEV
Han E® AV 16A Terminal Blocks
These Han E® AV inserts are rated at 16A. They are intended for use with hoods and housings contained within ranges 5, 6, 7, & 8. These housing ranges are associated to a specific Harting 'Size' number identifier. See the 'compatibility' table for details of this relationship, and stock numbers of housings that are typical of each range.