Teknik Belgeler
Özellikler
Marka
Honeywellİzlenen Ortam
Hydrogen Gas
Cihaz Tipi
Güçlendirilmemiş
Minimum Akış Hızı
-25 sccm
Maksimum Akış Hızı
25 cm³/s
Besleme Gerilimi
15 V dc
Boru Çapı Aralığı
0.246 in
Maksimum Basınç
150psi
Malzeme
Plastic
Minimum Çalışma Sıcaklığı
-40°C
Maksimum Çalışma Sıcaklığı
+125°C
Seri
AWM40000
Menşe
China
Ürün Ayrıntıları
Güçlendirilmiş Hava Akışı Sensörü Awm40000 Serisi
The AWM40000 Series mass flow sensor family is based on proven microbridge technology and includes both amplified signal conditioned devices and unamplified sensor only devices.
When using the unamplified devices (AWM42150VH and AWM42300V), the heater control circuit and the sensing bridge supply circuit are both required for operation per specification.
These two circuits are NOT on board the sensor and must be supplied in the application. The differential amplifier circuitry is useful in providing output gain and/or introducing voltage offsets to the sensor output.
The amplified devices (AWM43300V and AWM43600V) can be used to increase output gain and introduce voltage offsets.
The differential instrumentation amplifier circuitry, heater control circuitry and sensing bridge supply circuitry are all provided onboard the amplified sensors.
Stok bilgileri geçici olarak kullanılamıyor.
Ayrıntılı bilgi için iletşime geçiniz
Teklif İsteyiniz
1
Teklif İsteyiniz
1
Teknik Belgeler
Özellikler
Marka
Honeywellİzlenen Ortam
Hydrogen Gas
Cihaz Tipi
Güçlendirilmemiş
Minimum Akış Hızı
-25 sccm
Maksimum Akış Hızı
25 cm³/s
Besleme Gerilimi
15 V dc
Boru Çapı Aralığı
0.246 in
Maksimum Basınç
150psi
Malzeme
Plastic
Minimum Çalışma Sıcaklığı
-40°C
Maksimum Çalışma Sıcaklığı
+125°C
Seri
AWM40000
Menşe
China
Ürün Ayrıntıları
Güçlendirilmiş Hava Akışı Sensörü Awm40000 Serisi
The AWM40000 Series mass flow sensor family is based on proven microbridge technology and includes both amplified signal conditioned devices and unamplified sensor only devices.
When using the unamplified devices (AWM42150VH and AWM42300V), the heater control circuit and the sensing bridge supply circuit are both required for operation per specification.
These two circuits are NOT on board the sensor and must be supplied in the application. The differential amplifier circuitry is useful in providing output gain and/or introducing voltage offsets to the sensor output.
The amplified devices (AWM43300V and AWM43600V) can be used to increase output gain and introduce voltage offsets.
The differential instrumentation amplifier circuitry, heater control circuitry and sensing bridge supply circuitry are all provided onboard the amplified sensors.