Littelfuse, LSP05 Varistor, Varistor 277V

RS Stok Numarası: 173-2655Marka: LittelfuseÜretici Parça Numarası: LSP05277P
brand-logo
View all in Metal Oksit Varistörler

Teknik Belgeler

Özellikler

Varistör Gerilimi

277V

Maksimum AC Gerilim Değeri

320V

Malzeme

Metal

Seri

LSP05

Maksimum Ani Akım

10000A

Uzunluk

64mm

Derinlik

48mm

Kalınlık

30mm

Boyutlar

64 x 48 x 30mm

Menşe

China

Ürün Ayrıntıları

Littelfuse LSP05 Thermally Protected Varistor Module

LSP05 thermally protected varistor module designed for use in outdoor and commercial LED lighting fixtures for transient overvoltage protection. This thermally protected surge device has a parallel connection and a built-in thermal disconnect function that provides additional protection to prevent catastrophic failure and fire hazards. Additional features of this LSP05 thermally protected SPD include a maximum discharge current of 10kA 8/20μs, IP66 protection, indication wire lead options and a compact form factor of 48x48x30mm with mounting flanges. Typical applications for this LSP05 thermally protected varistor module include outdoor and commercial LED lighting, roadway lighting, traffic lighting, digital signage, street lighting and flood lighting.
Stock number 827-4331 is supplied without a GND wire connection, available for240Vac and 277Vac rating with CE marking for Class II unearth installation

Standards

Meets ANSI C136.2/ IEEE C62.41.2 Location Category C Low Exposure
CE Compliance IEC61643-11 Class II/ EN61643-11 Type 2

Transient Voltage Suppressors (Modules,Industrial)

Voltage surges, often referred to as spikes or transient overvoltages are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage surges are usually caused by lightning activity and can reach up to 6000V, with current surges of up to 3000A. The maximum size of the voltage and current surges depends on the location within the buildings wiring system. BS6651:1999 Annex C which was replaced in August 2008 by BS EN 62305-4:2006 is complemented by BS EN 61643-11/12 and covers location categories and provides guidance on protection of electronic equipment. For mains power systems, Types I, II and III are used. Surge protection devices not designed to fit into these categories may only provide limited protection and the equipment they protect may suffer damage.

Stok bilgileri geçici olarak kullanılamıyor.

Ayrıntılı bilgi için iletşime geçiniz

Stok bilgileri geçici olarak kullanılamıyor.

552,335 TL

Each (In a Bag of 8) KDV Hariç

662,802 TL

Each (In a Bag of 8) KDV Dahil

Littelfuse, LSP05 Varistor, Varistor 277V

552,335 TL

Each (In a Bag of 8) KDV Hariç

662,802 TL

Each (In a Bag of 8) KDV Dahil

Littelfuse, LSP05 Varistor, Varistor 277V
Stok bilgileri geçici olarak kullanılamıyor.

Teknik Belgeler

Özellikler

Varistör Gerilimi

277V

Maksimum AC Gerilim Değeri

320V

Malzeme

Metal

Seri

LSP05

Maksimum Ani Akım

10000A

Uzunluk

64mm

Derinlik

48mm

Kalınlık

30mm

Boyutlar

64 x 48 x 30mm

Menşe

China

Ürün Ayrıntıları

Littelfuse LSP05 Thermally Protected Varistor Module

LSP05 thermally protected varistor module designed for use in outdoor and commercial LED lighting fixtures for transient overvoltage protection. This thermally protected surge device has a parallel connection and a built-in thermal disconnect function that provides additional protection to prevent catastrophic failure and fire hazards. Additional features of this LSP05 thermally protected SPD include a maximum discharge current of 10kA 8/20μs, IP66 protection, indication wire lead options and a compact form factor of 48x48x30mm with mounting flanges. Typical applications for this LSP05 thermally protected varistor module include outdoor and commercial LED lighting, roadway lighting, traffic lighting, digital signage, street lighting and flood lighting.
Stock number 827-4331 is supplied without a GND wire connection, available for240Vac and 277Vac rating with CE marking for Class II unearth installation

Standards

Meets ANSI C136.2/ IEEE C62.41.2 Location Category C Low Exposure
CE Compliance IEC61643-11 Class II/ EN61643-11 Type 2

Transient Voltage Suppressors (Modules,Industrial)

Voltage surges, often referred to as spikes or transient overvoltages are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage surges are usually caused by lightning activity and can reach up to 6000V, with current surges of up to 3000A. The maximum size of the voltage and current surges depends on the location within the buildings wiring system. BS6651:1999 Annex C which was replaced in August 2008 by BS EN 62305-4:2006 is complemented by BS EN 61643-11/12 and covers location categories and provides guidance on protection of electronic equipment. For mains power systems, Types I, II and III are used. Surge protection devices not designed to fit into these categories may only provide limited protection and the equipment they protect may suffer damage.