Teknik Belgeler
Özellikler
Marka
ParkerÜrün Tipi
Pnömatik Zamanlayıcı
Tehlikeli Alan Sertifikası
Conforming to certificate LCIE 866115X, EExe ll T4
Montaj Tipi
DIN Rayı
Minimum Çalışma Basıncı
3bar
Maksimum Çalışma Basıncı
8 bar
Minimum Çalışma Sıcaklığı
-15°C
Maksimum Çalışma Sıcaklığı
60°C
Standartlar/Onaylar
EN 50014 dated March 1977 (NFC 23514 dated May 1982), EN 50019 dated March 1977 (NFC 23519 dated May 1982)
Ürün Ayrıntıları
Timer Module
A pneumatic timer consists of a solenoid coil/core, operating spring, timing disk, filter and diaphragm. The core moves up into the coil when it has been energized and this leads to pressure on the diaphragm. The diaphragm moves into the top chamber which un-traps the air through the timing disk. By altering the needle valve you can adjust the amount of delay.
Logic Systems
Logic units are best thought of as miniature valves, whose purpose is to influence the behaviour of larger power valves. They achieve this by producing and receiving output and input signals, using the common air supply. In this way, they are able to monitor and control a whole sequence of operations with great accuracy and repeatability.
Stok bilgileri geçici olarak kullanılamıyor.
13.722,77 TL
13.722,77 TL Each (KDV Hariç)
16.467,32 TL
16.467,32 TL Each KDV Dahil
1

13.722,77 TL
13.722,77 TL Each (KDV Hariç)
16.467,32 TL
16.467,32 TL Each KDV Dahil
Stok bilgileri geçici olarak kullanılamıyor.
1

| Miktar | Birim Fiyat |
|---|---|
| 1 - 4 | 13.722,77 TL |
| 5+ | 13.175,31 TL |
Teknik Belgeler
Özellikler
Marka
ParkerÜrün Tipi
Pnömatik Zamanlayıcı
Tehlikeli Alan Sertifikası
Conforming to certificate LCIE 866115X, EExe ll T4
Montaj Tipi
DIN Rayı
Minimum Çalışma Basıncı
3bar
Maksimum Çalışma Basıncı
8 bar
Minimum Çalışma Sıcaklığı
-15°C
Maksimum Çalışma Sıcaklığı
60°C
Standartlar/Onaylar
EN 50014 dated March 1977 (NFC 23514 dated May 1982), EN 50019 dated March 1977 (NFC 23519 dated May 1982)
Ürün Ayrıntıları
Timer Module
A pneumatic timer consists of a solenoid coil/core, operating spring, timing disk, filter and diaphragm. The core moves up into the coil when it has been energized and this leads to pressure on the diaphragm. The diaphragm moves into the top chamber which un-traps the air through the timing disk. By altering the needle valve you can adjust the amount of delay.
Logic Systems
Logic units are best thought of as miniature valves, whose purpose is to influence the behaviour of larger power valves. They achieve this by producing and receiving output and input signals, using the common air supply. In this way, they are able to monitor and control a whole sequence of operations with great accuracy and repeatability.