Phoenix Contact Koruyuculu Fiş, 20 V ac, 28 V dc, 20kA, PT 1X2-24DC-ST Serisi

RS Stok Numarası: 802-8201Marka: Phoenix ContactÜretici Parça Numarası: 2856032
brand-logo

Teknik Belgeler

Özellikler

Bastırıcı Tipi

Koruyucu Fiş

Maksimum Gerilim Değeri

20 V ac, 28 V dc

Montaj Tipi

DIN Rayı, Vida Montajı

Maksimum Ani Akım

20kA

Seri

PT 1X2-24DC-ST

Uzunluk

17.7mm

Derinlik

52mm

Yükseklik

45mm

Boyutlar

17.7 x 52 x 45mm

Minimum Çalışma Sıcaklığı

-40°C

Maksimum Çalışma Sıcaklığı

+85°C

Menşe

Germany

Ürün Ayrıntıları

PLUGTRAB PT- IQ Surge Protection System

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.

Stok bilgileri geçici olarak kullanılamıyor.

Ayrıntılı bilgi için iletşime geçiniz

Stok bilgileri geçici olarak kullanılamıyor.

3.349,18 TL

Each KDV Hariç

4.019,02 TL

Each KDV Dahil

Phoenix Contact Koruyuculu Fiş, 20 V ac, 28 V dc, 20kA, PT 1X2-24DC-ST Serisi

3.349,18 TL

Each KDV Hariç

4.019,02 TL

Each KDV Dahil

Phoenix Contact Koruyuculu Fiş, 20 V ac, 28 V dc, 20kA, PT 1X2-24DC-ST Serisi
Stok bilgileri geçici olarak kullanılamıyor.

Teknik Belgeler

Özellikler

Bastırıcı Tipi

Koruyucu Fiş

Maksimum Gerilim Değeri

20 V ac, 28 V dc

Montaj Tipi

DIN Rayı, Vida Montajı

Maksimum Ani Akım

20kA

Seri

PT 1X2-24DC-ST

Uzunluk

17.7mm

Derinlik

52mm

Yükseklik

45mm

Boyutlar

17.7 x 52 x 45mm

Minimum Çalışma Sıcaklığı

-40°C

Maksimum Çalışma Sıcaklığı

+85°C

Menşe

Germany

Ürün Ayrıntıları

PLUGTRAB PT- IQ Surge Protection System

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.