Pico Technology TA325 Akım Probu

Teknik Belgeler
Özellikler
Marka
pico TechnologyÜrün Tipi
Akım Probu
Maksimum DC Akım
30A
Maksimum AC Akım
3kA ac
Doğruluk
±1 %
Konnektör Tipi
D9
Minimum Çalışma Sıcaklığı
0°C
Maksimum Çalışma Sıcaklığı
50°C
Model Numarası
TA325
Standartlar/Onaylar
No
Güvenlik Kategorisi Gerilimi
1000V
Güvenlik Kategorisi Seviyesi
CAT III, Kategori IV
Menşe
United Kingdom
Ürün Ayrıntıları
Pico 30/300/3000 A AC 3-Phase Flex Current Probe with BNC Connector
The TA325 is a 3-phase AC current probe utilizing the Rogowski coil principle, used to measure AC current up to 3000 A when used with oscilloscopes, recorders or data loggers. The flexible probe allows current measurements on hard-to-reach conductors.
Rogowski coil technology has a couple of advantages over CT (current transformer) technology: when measuring multiple phases, the phase difference is small and predictable for higher frequency harmonic analysis applications; also, Rogowski coils do not have magnetic materials to saturate and so have excellent linearity.
The probes provide a 3 V full-scale AC output proportional to the current being measured with three selectable ranges: 30 A, 300 A and 3000 A.
When using the TA325 with a PicoScope 4444 differential scope, ensure that you purchase three TA271 D9-BNC adaptors. These can be found under the Accessories tab on this page.
Pico PC Based Instruments
Stok bilgileri geçici olarak kullanılamıyor.
Teklif İsteyiniz
1
Teklif İsteyiniz
Stok bilgileri geçici olarak kullanılamıyor.
1
Teknik Belgeler
Özellikler
Marka
pico TechnologyÜrün Tipi
Akım Probu
Maksimum DC Akım
30A
Maksimum AC Akım
3kA ac
Doğruluk
±1 %
Konnektör Tipi
D9
Minimum Çalışma Sıcaklığı
0°C
Maksimum Çalışma Sıcaklığı
50°C
Model Numarası
TA325
Standartlar/Onaylar
No
Güvenlik Kategorisi Gerilimi
1000V
Güvenlik Kategorisi Seviyesi
CAT III, Kategori IV
Menşe
United Kingdom
Ürün Ayrıntıları
Pico 30/300/3000 A AC 3-Phase Flex Current Probe with BNC Connector
The TA325 is a 3-phase AC current probe utilizing the Rogowski coil principle, used to measure AC current up to 3000 A when used with oscilloscopes, recorders or data loggers. The flexible probe allows current measurements on hard-to-reach conductors.
Rogowski coil technology has a couple of advantages over CT (current transformer) technology: when measuring multiple phases, the phase difference is small and predictable for higher frequency harmonic analysis applications; also, Rogowski coils do not have magnetic materials to saturate and so have excellent linearity.
The probes provide a 3 V full-scale AC output proportional to the current being measured with three selectable ranges: 30 A, 300 A and 3000 A.
When using the TA325 with a PicoScope 4444 differential scope, ensure that you purchase three TA271 D9-BNC adaptors. These can be found under the Accessories tab on this page.