Teknik Belgeler
Özellikler
Marka
Roxburgh EMCVaristör Gerilimi
240V
Maksimum AC Gerilim Değeri
275V
Maksimum DC Gerilim Değeri
350V
Malzeme
Metal
Enerji
264J
Seri
DVS
Maksimum Ani Akım
6500A
Uzunluk
75mm
Derinlik
52.5mm
Kalınlık
12.5mm
Boyutlar
75 x 52.5 x 12.5mm
Menşe
United Kingdom
Ürün Ayrıntıları
MOV Module, DVS Series
Modular slim-line transient voltage suppressors designed to snap-fit directly onto top hat profile DIN rails.
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.
Stok bilgileri geçici olarak kullanılamıyor.
2.745,14 TL
2.745,14 TL Each (KDV Hariç)
3.294,17 TL
3.294,17 TL Each KDV Dahil
1

2.745,14 TL
2.745,14 TL Each (KDV Hariç)
3.294,17 TL
3.294,17 TL Each KDV Dahil
Stok bilgileri geçici olarak kullanılamıyor.
1

| Miktar | Birim Fiyat |
|---|---|
| 1 - 9 | 2.745,14 TL |
| 10 - 24 | 2.545,62 TL |
| 25 - 49 | 2.360,02 TL |
| 50 - 99 | 2.034,64 TL |
| 100+ | 1.835,12 TL |
Teknik Belgeler
Özellikler
Marka
Roxburgh EMCVaristör Gerilimi
240V
Maksimum AC Gerilim Değeri
275V
Maksimum DC Gerilim Değeri
350V
Malzeme
Metal
Enerji
264J
Seri
DVS
Maksimum Ani Akım
6500A
Uzunluk
75mm
Derinlik
52.5mm
Kalınlık
12.5mm
Boyutlar
75 x 52.5 x 12.5mm
Menşe
United Kingdom
Ürün Ayrıntıları
MOV Module, DVS Series
Modular slim-line transient voltage suppressors designed to snap-fit directly onto top hat profile DIN rails.
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.