Teknik Belgeler
Özellikler
Controller Type
Detector
Ürün Tipi
Aydınlatma Kontrol Cihazı
Sensör Tipi
Cadmium Sulphide
Akım
8mA
Gerilim
220 to 270 V
Montaj Tipi
Remote
Dimmable
Yes
Çap
20 mm
Time Delay
45 s
Genişlik
31 mm
Yükseklik
25mm
Uzunluk
57mm
Güç
600mW
Standartlar/Onaylar
REACH, RoHS, EU
Seri
V9032
Menşe
United Kingdom
Ürün Ayrıntıları
2-Part Luminaire Controller
Supplied with
2 nitrile gaskets
Daylight Lighting Controllers
These controllers automatically turn lights 'ON' and 'OFF' in response to changes in ambient light levels, primarily the transition from day to night and vice-versa. The more advanced types (see note below) have inbuilt logic to minimise false triggering, whereas the remainder have inbuilt time delays or higher 'OFF' thresholds, to prevent on/off cycling. As a general rule, these controllers should be sited such that they are not illuminated, by the light they are controlling. Nominal supply voltage is 230Vac.,Note regarding energy-saving negative-hysteresis controllers,Where figures for the 'OFF' threshold are lower than for the 'ON' threshold, the sensor is designed such that four thresholds are actually monitored. These are: dusk, the middle of the night, dawn and the middle of the day. Monitoring at times other than dusk and dawn enables the sensor to determine what it should be looking for next, minimising false triggering and improving overall controller operation.
Stok bilgileri geçici olarak kullanılamıyor.
Teklif İsteyiniz
1

Teklif İsteyiniz
Stok bilgileri geçici olarak kullanılamıyor.
1

Teknik Belgeler
Özellikler
Controller Type
Detector
Ürün Tipi
Aydınlatma Kontrol Cihazı
Sensör Tipi
Cadmium Sulphide
Akım
8mA
Gerilim
220 to 270 V
Montaj Tipi
Remote
Dimmable
Yes
Çap
20 mm
Time Delay
45 s
Genişlik
31 mm
Yükseklik
25mm
Uzunluk
57mm
Güç
600mW
Standartlar/Onaylar
REACH, RoHS, EU
Seri
V9032
Menşe
United Kingdom
Ürün Ayrıntıları
2-Part Luminaire Controller
Supplied with
2 nitrile gaskets
Daylight Lighting Controllers
These controllers automatically turn lights 'ON' and 'OFF' in response to changes in ambient light levels, primarily the transition from day to night and vice-versa. The more advanced types (see note below) have inbuilt logic to minimise false triggering, whereas the remainder have inbuilt time delays or higher 'OFF' thresholds, to prevent on/off cycling. As a general rule, these controllers should be sited such that they are not illuminated, by the light they are controlling. Nominal supply voltage is 230Vac.,Note regarding energy-saving negative-hysteresis controllers,Where figures for the 'OFF' threshold are lower than for the 'ON' threshold, the sensor is designed such that four thresholds are actually monitored. These are: dusk, the middle of the night, dawn and the middle of the day. Monitoring at times other than dusk and dawn enables the sensor to determine what it should be looking for next, minimising false triggering and improving overall controller operation.