RS PRO Koaksiyel Hat Arestörü, 90 V, 10kA
Teknik Belgeler
Özellikler
Marka
RS ProBastırıcı Tipi
Koaksiyel Hat Durdurucu
Maksimum Gerilim Değeri
90 V
Maksimum Ani Akım
10kA
Minimum Çalışma Sıcaklığı
-30°C
Maksimum Çalışma Sıcaklığı
+80°C
Ürün Ayrıntıları
Surge Protectors
These high-energy surge and lighting arrestors have a wide band-width, low VSWR and low insertion loss. Applications include Telemetry, Fixed/Mobile Communication Systems including both transmitters and receivers. The devices have an M5 stud on the base so that they can be chassis mounted, alternatively, they can be mounted on a single-way mounting bracket (288-193) Available in 'N'; BNC and UHF types with female connectors. Maximum transmitted power through the devices is 144W at 50Ω. The protective element is a low capacitance, gas arrestor. Maximum surge current is 10kA and their good frequency specification is achieved by using a silver plated, precision turned body. These devices are factory sealed and no maintenance is required.
Warning
These coax line protectors must be earthed for maximum protection.
In-line Component Cases & Coaxial Line Surge Protectors
Stok bilgileri geçici olarak kullanılamıyor.
Ayrıntılı bilgi için iletşime geçiniz
4.316,60 TL
Each KDV Hariç
5.179,92 TL
Each KDV Dahil
1
4.316,60 TL
Each KDV Hariç
5.179,92 TL
Each KDV Dahil
1
Toptan Satın Al
Miktar | Birim Fiyat |
---|---|
1 - 9 | 4.316,60 TL |
10 - 24 | 3.636,25 TL |
25 - 49 | 3.274,48 TL |
50 - 99 | 2.948,48 TL |
100+ | 2.655,90 TL |
Teknik Belgeler
Özellikler
Marka
RS ProBastırıcı Tipi
Koaksiyel Hat Durdurucu
Maksimum Gerilim Değeri
90 V
Maksimum Ani Akım
10kA
Minimum Çalışma Sıcaklığı
-30°C
Maksimum Çalışma Sıcaklığı
+80°C
Ürün Ayrıntıları
Surge Protectors
These high-energy surge and lighting arrestors have a wide band-width, low VSWR and low insertion loss. Applications include Telemetry, Fixed/Mobile Communication Systems including both transmitters and receivers. The devices have an M5 stud on the base so that they can be chassis mounted, alternatively, they can be mounted on a single-way mounting bracket (288-193) Available in 'N'; BNC and UHF types with female connectors. Maximum transmitted power through the devices is 144W at 50Ω. The protective element is a low capacitance, gas arrestor. Maximum surge current is 10kA and their good frequency specification is achieved by using a silver plated, precision turned body. These devices are factory sealed and no maintenance is required.
Warning
These coax line protectors must be earthed for maximum protection.