RS PRO Surge Suppressor Unit 253 V Maximum Voltage Rating 6.5kA Maximum Surge Current EMC Filter

RS Stok Numarası: 206-7926Marka: RS PRO
brand-logo

Teknik Belgeler

Özellikler

Marka

RS Pro

Bastırıcı Tipi

EMC Filtresi

Maksimum Gerilim Değeri

253 V

Montaj Tipi

DIN Rayı

Maksimum Ani Akım

6.5kA

Seri

MAXX

Minimum Çalışma Sıcaklığı

-25°C

Maksimum Çalışma Sıcaklığı

+85°C

Ürün Ayrıntıları

Surge & Noise Suppressor, MAxx / D Series

Combined surge and RFI filter units

Warning

Will not pass a 500V insulation test.

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.

Stok bilgileri geçici olarak kullanılamıyor.

Ayrıntılı bilgi için iletşime geçiniz

Stok bilgileri geçici olarak kullanılamıyor.

10.710,60 TL

Each KDV Hariç

12.852,72 TL

Each KDV Dahil

RS PRO Surge Suppressor Unit 253 V Maximum Voltage Rating 6.5kA Maximum Surge Current EMC Filter
sticker-359

10.710,60 TL

Each KDV Hariç

12.852,72 TL

Each KDV Dahil

RS PRO Surge Suppressor Unit 253 V Maximum Voltage Rating 6.5kA Maximum Surge Current EMC Filter
Stok bilgileri geçici olarak kullanılamıyor.
sticker-359

Toptan Satın Al

MiktarBirim Fiyat
1 - 110.710,60 TL
2 - 410.283,00 TL
5+9.749,00 TL

Teknik Belgeler

Özellikler

Marka

RS Pro

Bastırıcı Tipi

EMC Filtresi

Maksimum Gerilim Değeri

253 V

Montaj Tipi

DIN Rayı

Maksimum Ani Akım

6.5kA

Seri

MAXX

Minimum Çalışma Sıcaklığı

-25°C

Maksimum Çalışma Sıcaklığı

+85°C

Ürün Ayrıntıları

Surge & Noise Suppressor, MAxx / D Series

Combined surge and RFI filter units

Warning

Will not pass a 500V insulation test.

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.