RS PRO Type K Mineral Insulated Thermocouple 500mm Length, 0.5mm Diameter → +750°C

RS Stok Numarası: 444-1253Marka: RS PRO
brand-logo

Teknik Belgeler

Özellikler

Marka

RS Pro

Termoeleman Tipi

K

Prob Çapı

0.5mm

Prob Uzunluğu

500mm

Prob Malzemesi

Paslanmaz Çelik

Maksimum Algılanan Sıcaklık

+750°C

Sonlandırma Tipi

Kablo

Kablo Uzunluğu

100mm

Karşılanan Standartlar

IEC

Menşe

United Kingdom

Ürün Ayrıntıları

Type K Industrial Mineral Insulated Probe, Underground Junction

Type K Thermocouples is a device which measures temperatures, it’s made up from two wires which are different materials. When these two wires are joined together, they create an electrical junction. Once the temperature changes at this junction, it created a voltage which can then be interpreted and read as a temperature. This is commonly known as the “Seebeck Effect”.

Standards

Colour coded to IEC 584

Stok bilgileri geçici olarak kullanılamıyor.

Ayrıntılı bilgi için iletşime geçiniz

Stok bilgileri geçici olarak kullanılamıyor.

1.599,13 TL

Each (KDV Hariç)

1.918,96 TL

Each KDV Dahil

RS PRO Type K Mineral Insulated Thermocouple 500mm Length, 0.5mm Diameter → +750°C
sticker-359

1.599,13 TL

Each (KDV Hariç)

1.918,96 TL

Each KDV Dahil

RS PRO Type K Mineral Insulated Thermocouple 500mm Length, 0.5mm Diameter → +750°C
Stok bilgileri geçici olarak kullanılamıyor.
sticker-359

Toptan Satın Al

MiktarBirim Fiyat
1 - 41.599,13 TL
5 - 91.550,72 TL
10+1.487,27 TL

Teknik Belgeler

Özellikler

Marka

RS Pro

Termoeleman Tipi

K

Prob Çapı

0.5mm

Prob Uzunluğu

500mm

Prob Malzemesi

Paslanmaz Çelik

Maksimum Algılanan Sıcaklık

+750°C

Sonlandırma Tipi

Kablo

Kablo Uzunluğu

100mm

Karşılanan Standartlar

IEC

Menşe

United Kingdom

Ürün Ayrıntıları

Type K Industrial Mineral Insulated Probe, Underground Junction

Type K Thermocouples is a device which measures temperatures, it’s made up from two wires which are different materials. When these two wires are joined together, they create an electrical junction. Once the temperature changes at this junction, it created a voltage which can then be interpreted and read as a temperature. This is commonly known as the “Seebeck Effect”.

Standards

Colour coded to IEC 584