Teknik Belgeler
Özellikler
Marka
Sato PartsSigorta Tutucu Tipi
Panele Monte
Sigorta Boyutu
5 x 20 mm, 6.3 x 32 mm
Başlık Stili
Manuel
Uyumlu Sigorta Çapı
5 mm, 6.3 mm
Koruma Kategorisi
PC1, PC2, PC3
Uyumlu Sigorta Uzunluğu
20 mm, 32 mm
Menşe
Japan
Ürün Ayrıntıları
Fuse holder, panel-mounting type
Panel Mounting
CATEGORIES OF PROTECTION AGAINST ELECTRIC SHOCK,PC1: No integral protection against electric shock. If required, designers must provide additional protection against electric shock on equipment.,PC2: With integral protection against electric shock. Fuse-holders shall have live parts inaccessible to IEC529 standard test finger, when fully assembled, without fuse carrier or fuse in place and when fuse carrier, with fuse is being inserted or withdrawn.,PC3: With integral protection against electric shock. Fuse-holders shall have live parts inaccessible to IEC529 1mm diameter rigid test wire when fully assembled, without fuse carrier or fuse in place and when fuse carrier, with fuse is being inserted or withdrawn.
Stok bilgileri geçici olarak kullanılamıyor.
Ayrıntılı bilgi için iletşime geçiniz
705,24 TL
141,047 TL Each (In a Pack of 5) (KDV Hariç)
846,29 TL
169,256 TL Each (In a Pack of 5) KDV Dahil
5
705,24 TL
141,047 TL Each (In a Pack of 5) (KDV Hariç)
846,29 TL
169,256 TL Each (In a Pack of 5) KDV Dahil
5
Toptan Satın Al
Miktar | Birim Fiyat | Per Paket |
---|---|---|
25 - 25 | 141,047 TL | 3.526,18 TL |
50+ | 136,253 TL | 3.406,32 TL |
Teknik Belgeler
Özellikler
Marka
Sato PartsSigorta Tutucu Tipi
Panele Monte
Sigorta Boyutu
5 x 20 mm, 6.3 x 32 mm
Başlık Stili
Manuel
Uyumlu Sigorta Çapı
5 mm, 6.3 mm
Koruma Kategorisi
PC1, PC2, PC3
Uyumlu Sigorta Uzunluğu
20 mm, 32 mm
Menşe
Japan
Ürün Ayrıntıları
Fuse holder, panel-mounting type
Panel Mounting
CATEGORIES OF PROTECTION AGAINST ELECTRIC SHOCK,PC1: No integral protection against electric shock. If required, designers must provide additional protection against electric shock on equipment.,PC2: With integral protection against electric shock. Fuse-holders shall have live parts inaccessible to IEC529 standard test finger, when fully assembled, without fuse carrier or fuse in place and when fuse carrier, with fuse is being inserted or withdrawn.,PC3: With integral protection against electric shock. Fuse-holders shall have live parts inaccessible to IEC529 1mm diameter rigid test wire when fully assembled, without fuse carrier or fuse in place and when fuse carrier, with fuse is being inserted or withdrawn.