Teknik Belgeler
Özellikler
Marka
SickAralık
Flexi Soft
Seri
FX3
Güvenlik Girişlerinin Sayısı
96
Güvenlik Çıkışlarının Sayısı
48
Güvenlik Kategorisi
4
SIL
SIL 3
Besleme Gerilimi
24 V dc
Kontak Akımı Değeri
4 A
IP Değeri
IP20
Boyutlar
96,5 x 22,5 x 120,8 mm
Derinlik
120.8mm
Uzunluk
96.5mm
Genişlik
22.5mm
Ürün Ayrıntıları
Flexi Soft Safety Controller, Main unit - FX3 CPU000000
Flexi Soft is a programmable and modularly expandable safety controller capable of being integrated into various networks. The main module FX3-CPU is the CPU of the entire system within which all input signals are monitored and processed via the safety logic stored in the memory plug. These signals are then used to switch outputs on the system through the FLEX BUS+ interface which connects all units to one another. The main unit has an RS-232 interface with which the Flexi Soft Designer can upload and change system settings. The RS-232 port can be used for permanent diagnosis (i.e. PLC or HMI) as well.,Functions: EDM, muting, operating mode switching. Logical functions: AND, NOT, OR, XNOR, XOR. Application specific logical functions: operating mode switch, muting, emergency stop, presses, two hand control.,For the integration of Flexi Soft data into an existing PLC, up to two gateways can be added to a system. The gateways provide I/O Status and Error/Status Messaging. Additionally, non-safety related information can be sent to the Flexi Soft from the network. Each gateway can send and receive at least 50 Bytes of information.
Stok bilgileri geçici olarak kullanılamıyor.
Ayrıntılı bilgi için iletşime geçiniz
Teklif İsteyiniz
1
Teklif İsteyiniz
1
Teknik Belgeler
Özellikler
Marka
SickAralık
Flexi Soft
Seri
FX3
Güvenlik Girişlerinin Sayısı
96
Güvenlik Çıkışlarının Sayısı
48
Güvenlik Kategorisi
4
SIL
SIL 3
Besleme Gerilimi
24 V dc
Kontak Akımı Değeri
4 A
IP Değeri
IP20
Boyutlar
96,5 x 22,5 x 120,8 mm
Derinlik
120.8mm
Uzunluk
96.5mm
Genişlik
22.5mm
Ürün Ayrıntıları
Flexi Soft Safety Controller, Main unit - FX3 CPU000000
Flexi Soft is a programmable and modularly expandable safety controller capable of being integrated into various networks. The main module FX3-CPU is the CPU of the entire system within which all input signals are monitored and processed via the safety logic stored in the memory plug. These signals are then used to switch outputs on the system through the FLEX BUS+ interface which connects all units to one another. The main unit has an RS-232 interface with which the Flexi Soft Designer can upload and change system settings. The RS-232 port can be used for permanent diagnosis (i.e. PLC or HMI) as well.,Functions: EDM, muting, operating mode switching. Logical functions: AND, NOT, OR, XNOR, XOR. Application specific logical functions: operating mode switch, muting, emergency stop, presses, two hand control.,For the integration of Flexi Soft data into an existing PLC, up to two gateways can be added to a system. The gateways provide I/O Status and Error/Status Messaging. Additionally, non-safety related information can be sent to the Flexi Soft from the network. Each gateway can send and receive at least 50 Bytes of information.