Teknik Belgeler
Özellikler
Marka
TektronixŞununla Birlikte Kullanım İçin
TDS400 Serisi, TDS500 Serisi, TDS5000 Serisi, TDS600 Serisi, TDS700 Serisi, TDS7000 Serisi
Model Number p
ADA400A
Menşe
United States
Ürün Ayrıntıları
Tektronix ADA400A 1 MHz Differential Preamplifier
The ADA400A Active Differential Preamplifier allows direct oscilloscope measurements of very low amplitude voltages and signals which are not ground referenced. The high impedance of both inputs eliminates the need to add additional ground points in the DUT, thereby avoiding circulating currents which disturb the measurement or the circuit.,The high gain and extremely high common mode rejection provide usable measurements of voltages as low as 5μV, even in high noise environments. Selectable bandwidth limiting reduces normal mode noise from digital logic, switch mode power supplies and line frequency sources. Adjustable differential offset allows the user to null out transducer bridge bias and galvanic potential from the test set-up. An "infinite impedance" mode can be selected in the two highest gain ranges allowing accurate measurements of signals with high source impedance. It is specifically designed to operate on Tektronix oscilloscopes with TEKPROBE® interface
Stok bilgileri geçici olarak kullanılamıyor.
Ayrıntılı bilgi için iletşime geçiniz
Teklif İsteyiniz
1
Teklif İsteyiniz
1
Teknik Belgeler
Özellikler
Marka
TektronixŞununla Birlikte Kullanım İçin
TDS400 Serisi, TDS500 Serisi, TDS5000 Serisi, TDS600 Serisi, TDS700 Serisi, TDS7000 Serisi
Model Number p
ADA400A
Menşe
United States
Ürün Ayrıntıları
Tektronix ADA400A 1 MHz Differential Preamplifier
The ADA400A Active Differential Preamplifier allows direct oscilloscope measurements of very low amplitude voltages and signals which are not ground referenced. The high impedance of both inputs eliminates the need to add additional ground points in the DUT, thereby avoiding circulating currents which disturb the measurement or the circuit.,The high gain and extremely high common mode rejection provide usable measurements of voltages as low as 5μV, even in high noise environments. Selectable bandwidth limiting reduces normal mode noise from digital logic, switch mode power supplies and line frequency sources. Adjustable differential offset allows the user to null out transducer bridge bias and galvanic potential from the test set-up. An "infinite impedance" mode can be selected in the two highest gain ranges allowing accurate measurements of signals with high source impedance. It is specifically designed to operate on Tektronix oscilloscopes with TEKPROBE® interface