Teknik Belgeler
Özellikler
Marka
DTSTip
Bölmeli
Bölge Sınıflandırması
1, 2, 21, 22
Sıcaklık Sınıflandırması
T4, T5
Vat Miktarı
18 W
Lamba Tipi
Floresan
Tek Lamba Vat Miktarı
18W
Lambaların Sayısı
1
Tehlikeli Alan Sertifikası
ATEX
Menşe
France
Ürün Ayrıntıları
Emergency Hazardous Fitting, Zone 1, 2, 21 & 22 Ex-e
The EVS-EMA Series from DTS is an emergency lighting hazardous area Ex e fluorescent luminaries, is designed for use in Zone 1, 2, 21, and 22 areas, allowing the same emergency luminaries to be used across the whole of a hazardous area site at the same time meeting the requirements of the evacuation standards. The EVS-EMA ATEX luminaries combine high quality with a large range of features.
Supplied with
One nylon M20 cable gland cable (6-12mm), two M20 nylon plugs & two zinc plated steel brackets for ceiling mounting (V015)
Approvals
EN60079-.0, 60079-1, 60079-5, 60079-7, 61241-1
LCIE 11 ATEX 3065X
IEC Ex LCI 11,0053X
Ex II 2 G
Ex de IIC T4 Gb for ≤ -40°C to ≤ +60°C
Ex de IIC T5 Gb for ≤ -40°C to ≤ +35°C
Ex II 2 D, Ex tb IIIC T85°C Db IP6x
IEC 60529 (2001) IP66
Emergency Light Fittings
There are two basic types of emergency lighting luminaires - maintained and non-maintained.
Maintained, these luminaires have the advantage of being able to be switched between the maintained function (lamp illuminated at all times) and non-maintained (lamp off until power supply fails), making them ideal for applications such as corridors, workshops and permanently illuminated emergency exit signs. The maintained luminaires also have the facility of being switched in banks of up to ten units.
Non-maintained, these luminaires are only illuminated on a failure of the mains supply. Ideal for emergency exits, switchrooms and storage areas.
Stok bilgileri geçici olarak kullanılamıyor.
Ayrıntılı bilgi için iletşime geçiniz
P.O.A.
1
P.O.A.
1
Teknik Belgeler
Özellikler
Marka
DTSTip
Bölmeli
Bölge Sınıflandırması
1, 2, 21, 22
Sıcaklık Sınıflandırması
T4, T5
Vat Miktarı
18 W
Lamba Tipi
Floresan
Tek Lamba Vat Miktarı
18W
Lambaların Sayısı
1
Tehlikeli Alan Sertifikası
ATEX
Menşe
France
Ürün Ayrıntıları
Emergency Hazardous Fitting, Zone 1, 2, 21 & 22 Ex-e
The EVS-EMA Series from DTS is an emergency lighting hazardous area Ex e fluorescent luminaries, is designed for use in Zone 1, 2, 21, and 22 areas, allowing the same emergency luminaries to be used across the whole of a hazardous area site at the same time meeting the requirements of the evacuation standards. The EVS-EMA ATEX luminaries combine high quality with a large range of features.
Supplied with
One nylon M20 cable gland cable (6-12mm), two M20 nylon plugs & two zinc plated steel brackets for ceiling mounting (V015)
Approvals
EN60079-.0, 60079-1, 60079-5, 60079-7, 61241-1
LCIE 11 ATEX 3065X
IEC Ex LCI 11,0053X
Ex II 2 G
Ex de IIC T4 Gb for ≤ -40°C to ≤ +60°C
Ex de IIC T5 Gb for ≤ -40°C to ≤ +35°C
Ex II 2 D, Ex tb IIIC T85°C Db IP6x
IEC 60529 (2001) IP66
Emergency Light Fittings
There are two basic types of emergency lighting luminaires - maintained and non-maintained.
Maintained, these luminaires have the advantage of being able to be switched between the maintained function (lamp illuminated at all times) and non-maintained (lamp off until power supply fails), making them ideal for applications such as corridors, workshops and permanently illuminated emergency exit signs. The maintained luminaires also have the facility of being switched in banks of up to ten units.
Non-maintained, these luminaires are only illuminated on a failure of the mains supply. Ideal for emergency exits, switchrooms and storage areas.