Teknik Belgeler
Özellikler
Marka
ABBKutupların Sayısı
1
Ürün Tipi
Minyatür Devre Kesici
Akım Değeri
6A
Kesme Özellikleri
C Tipi
Nominal AC Gerilimi
253V ac
Nominal DC Gerilimi
72V dc
Kesme Kapasitesi
6kA
Montaj Tipi
DIN Rayı
Aralık
System Pro M Compact
Seri
System Pro M Compact
Terminal Tipi
Vida
IP Değeri
IP40, IP20
Yükseklik
88mm
Derinlik
69mm
Standartlar/Onaylar
IEC/EN 60947-2, IEC/EN 60898-1
Genişlik
17.5mm
Kesme Mekanizması
Termal
Menşe
Germany
Ürün Ayrıntıları
Safeguard your appliances from electrical faults with this MCB from ABB. It features a delayed thermal tripping system for overload protection and an electromagnetic tripping mechanism to prevent damage from short circuit faults. With maximum operating voltages of 253V on AC circuits and 72V on DC networks, the device is designed for low-voltage applications. As it has type-C characteristics, it will trip at 5 to 10 times its 6A rated current, making it suitable for handling inductive loads with a high chance of short circuits.
The breaking capacity of a circuit breaker is the amount of current that it can interrupt without suffering damage. This unit has a breaking capacity of 6kA, so you can use it in settings prone to high current surges.
Stok bilgileri geçici olarak kullanılamıyor.
Teklif İsteyiniz
1

Teklif İsteyiniz
Stok bilgileri geçici olarak kullanılamıyor.
1

Teknik Belgeler
Özellikler
Marka
ABBKutupların Sayısı
1
Ürün Tipi
Minyatür Devre Kesici
Akım Değeri
6A
Kesme Özellikleri
C Tipi
Nominal AC Gerilimi
253V ac
Nominal DC Gerilimi
72V dc
Kesme Kapasitesi
6kA
Montaj Tipi
DIN Rayı
Aralık
System Pro M Compact
Seri
System Pro M Compact
Terminal Tipi
Vida
IP Değeri
IP40, IP20
Yükseklik
88mm
Derinlik
69mm
Standartlar/Onaylar
IEC/EN 60947-2, IEC/EN 60898-1
Genişlik
17.5mm
Kesme Mekanizması
Termal
Menşe
Germany
Ürün Ayrıntıları
Safeguard your appliances from electrical faults with this MCB from ABB. It features a delayed thermal tripping system for overload protection and an electromagnetic tripping mechanism to prevent damage from short circuit faults. With maximum operating voltages of 253V on AC circuits and 72V on DC networks, the device is designed for low-voltage applications. As it has type-C characteristics, it will trip at 5 to 10 times its 6A rated current, making it suitable for handling inductive loads with a high chance of short circuits.
The breaking capacity of a circuit breaker is the amount of current that it can interrupt without suffering damage. This unit has a breaking capacity of 6kA, so you can use it in settings prone to high current surges.