Teknik Belgeler
Özellikler
Marka
HartingÜrün Tipi
Menteşeli Çerçeve
Aksesuar Tipi
Metal Frame
Boyut
10B
Kablo Giriş Açısı
Üst
Renk
Gri
Kontakların Sayısı
2
Seri
Han Modular
Şununla Birlikte Kullanım İçin
Standard Han Hoods and Housings
Malzeme
Basınçlı Çinko Döküm
Standartlar/Onaylar
CSA, DNV GL, UL
Diş Boyutu
M3
Minimum Tel Boyutu (mm²)
4mm²
Maksimum Tel Boyutu (mm²)
10mm²
Menşe
Germany
Ürün Ayrıntıları
This hinged frame provides a top-entry metal mounting solution for modular connector hoods and housings. Designed for three-module A to C arrangements, it delivers a Durable Interface between standard Han hoods and enclosures. The unit is intended for industrial installations requiring a hinged access point and supports both power and signal conductor connections within defined conductor cross-sections.
It is specified to operate between -40 to +125°C.
It is approved under UL and CSA standards and has DNV GL recognition.
Signal-side conductor cross-sections are specified as 1 to 2.5mm².
Recommended tightening torques are 0.8 Nm for M3 and 1.2 Nm for M4 PE screws.
The 1 module is for use with hoods and housings from range 2 – the Harting 10A Series (see stock no. 181-0662 which is typical of that range)
Stok bilgileri geçici olarak kullanılamıyor.
Teklif İsteyiniz
Each (In a Pack of 2) (KDV Hariç)
2
Teklif İsteyiniz
Each (In a Pack of 2) (KDV Hariç)
Stok bilgileri geçici olarak kullanılamıyor.
2
Teknik Belgeler
Özellikler
Marka
HartingÜrün Tipi
Menteşeli Çerçeve
Aksesuar Tipi
Metal Frame
Boyut
10B
Kablo Giriş Açısı
Üst
Renk
Gri
Kontakların Sayısı
2
Seri
Han Modular
Şununla Birlikte Kullanım İçin
Standard Han Hoods and Housings
Malzeme
Basınçlı Çinko Döküm
Standartlar/Onaylar
CSA, DNV GL, UL
Diş Boyutu
M3
Minimum Tel Boyutu (mm²)
4mm²
Maksimum Tel Boyutu (mm²)
10mm²
Menşe
Germany
Ürün Ayrıntıları
This hinged frame provides a top-entry metal mounting solution for modular connector hoods and housings. Designed for three-module A to C arrangements, it delivers a Durable Interface between standard Han hoods and enclosures. The unit is intended for industrial installations requiring a hinged access point and supports both power and signal conductor connections within defined conductor cross-sections.
It is specified to operate between -40 to +125°C.
It is approved under UL and CSA standards and has DNV GL recognition.
Signal-side conductor cross-sections are specified as 1 to 2.5mm².
Recommended tightening torques are 0.8 Nm for M3 and 1.2 Nm for M4 PE screws.
The 1 module is for use with hoods and housings from range 2 – the Harting 10A Series (see stock no. 181-0662 which is typical of that range)