Teknik Belgeler
Özellikler
Marka
LittelfuseÜrün Tipi
Panel Mount Fuse Cover
Seri
816
Uyumlu Sigorta Boyutu
6.3 x 32 mm
Sigorta Tutucu Montaj Tipi
Gömme
Uzunluk
33.8mm
Yükseklik
33.8mm
Kapak Malzemesi
Poliamit
Standartlar/Onaylar
UL, CSA
IP Değeri
IP64, IP40
Şununla Birlikte Kullanım İçin
6,3 x 32 mm Sigorta
Ürün Ayrıntıları
Littelfuse fuseholders and clips offer a comprehensive solution to a variety of application requirements.
CATEGORIES OF PROTECTION AGAINST ELECTRIC SHOCK,PC1: No integral protection against electric shock. If required, designers must provide additional protection against electric shock on equipment.,PC2: With integral protection against electric shock. Fuse-holders shall have live parts inaccessible to IEC529 standard test finger, when fully assembled, without fuse carrier or fuse in place and when fuse carrier, with fuse is being inserted or withdrawn.,PC3: With integral protection against electric shock. Fuse-holders shall have live parts inaccessible to IEC529 1mm diameter rigid test wire when fully assembled, without fuse carrier or fuse in place and when fuse carrier, with fuse is being inserted or withdrawn.
Caps supplied separately
Stok bilgileri geçici olarak kullanılamıyor.
Teklif İsteyiniz
Each (In a Pack of 5) (KDV Hariç)
5

Teklif İsteyiniz
Each (In a Pack of 5) (KDV Hariç)
Stok bilgileri geçici olarak kullanılamıyor.
5

Teknik Belgeler
Özellikler
Marka
LittelfuseÜrün Tipi
Panel Mount Fuse Cover
Seri
816
Uyumlu Sigorta Boyutu
6.3 x 32 mm
Sigorta Tutucu Montaj Tipi
Gömme
Uzunluk
33.8mm
Yükseklik
33.8mm
Kapak Malzemesi
Poliamit
Standartlar/Onaylar
UL, CSA
IP Değeri
IP64, IP40
Şununla Birlikte Kullanım İçin
6,3 x 32 mm Sigorta
Ürün Ayrıntıları
Littelfuse fuseholders and clips offer a comprehensive solution to a variety of application requirements.
CATEGORIES OF PROTECTION AGAINST ELECTRIC SHOCK,PC1: No integral protection against electric shock. If required, designers must provide additional protection against electric shock on equipment.,PC2: With integral protection against electric shock. Fuse-holders shall have live parts inaccessible to IEC529 standard test finger, when fully assembled, without fuse carrier or fuse in place and when fuse carrier, with fuse is being inserted or withdrawn.,PC3: With integral protection against electric shock. Fuse-holders shall have live parts inaccessible to IEC529 1mm diameter rigid test wire when fully assembled, without fuse carrier or fuse in place and when fuse carrier, with fuse is being inserted or withdrawn.
Caps supplied separately