Teknik Belgeler
Özellikler
Marka
PR ElectronicsKanalların Sayısı
2
Ürün Tipi
Galvanic Barrier
Barrier Type
Galvanic Barrier
Montaj Tipi
DIN Rayı
Tehlikeli Alan Sertifikası
IECEx, ATEX
Terminal Tipi
Vida
IP Değeri
IP20
Besleme Gerilimi
19.2 to 300 V dc, 21.6 to 253 V ac
Maximum Safety Current
400mA
Minimum Çalışma Sıcaklığı
-20°C
Signal Type
Pulse
Maximum Safety Voltage
300V
Maksimum Çalışma Sıcaklığı
60°C
Standartlar/Onaylar
TR-CU 020/2011, 2014/35/EU, EN 60947-5-6, 2014/30/EU, PELV/SELV IEC 61140
Seri
5200
Menşe
Denmark
Ürün Ayrıntıları
PR Electronics 5202B Ex Pulse Isolator
PR Electronics 5202B pulse isolator for transmission of signals to the safe area from NAMUR sensors installed in hazardous areas. This signal conditioning isolator measures one or more pulse inputs and provides an identical number of isolated pulse outputs. The PR 5202B uses transformer and optical isolation techniques to provide 3.75 kVac galvanic isolation between the input, output and power terminals. The high level of electrical isolation means that input pulses sensed at the 5202B are not electrically connected to the output pulse. The 5202B has been designed, developed and certified for use in SIL 2 applications according to the requirements of IEC 61508.
Besides providing isolation, the PR 5202B is a barrier. This means that the module can make an intrinsically safe measurement of contacts and NAMUR sensors mounted in a zone 0/ Division 1 explosion hazard area. The PR 5202B limits the level of energy present at the contact or the NAMUR sensor to a low intrinsically safe level, thereby preventing ignition of a flammable atmosphere around the sensor – even if the sensor or the cable is damaged.
PR Electronics - Ex Interfaces
Stok bilgileri geçici olarak kullanılamıyor.
Teklif İsteyiniz
1
Teklif İsteyiniz
Stok bilgileri geçici olarak kullanılamıyor.
1
Teknik Belgeler
Özellikler
Marka
PR ElectronicsKanalların Sayısı
2
Ürün Tipi
Galvanic Barrier
Barrier Type
Galvanic Barrier
Montaj Tipi
DIN Rayı
Tehlikeli Alan Sertifikası
IECEx, ATEX
Terminal Tipi
Vida
IP Değeri
IP20
Besleme Gerilimi
19.2 to 300 V dc, 21.6 to 253 V ac
Maximum Safety Current
400mA
Minimum Çalışma Sıcaklığı
-20°C
Signal Type
Pulse
Maximum Safety Voltage
300V
Maksimum Çalışma Sıcaklığı
60°C
Standartlar/Onaylar
TR-CU 020/2011, 2014/35/EU, EN 60947-5-6, 2014/30/EU, PELV/SELV IEC 61140
Seri
5200
Menşe
Denmark
Ürün Ayrıntıları
PR Electronics 5202B Ex Pulse Isolator
PR Electronics 5202B pulse isolator for transmission of signals to the safe area from NAMUR sensors installed in hazardous areas. This signal conditioning isolator measures one or more pulse inputs and provides an identical number of isolated pulse outputs. The PR 5202B uses transformer and optical isolation techniques to provide 3.75 kVac galvanic isolation between the input, output and power terminals. The high level of electrical isolation means that input pulses sensed at the 5202B are not electrically connected to the output pulse. The 5202B has been designed, developed and certified for use in SIL 2 applications according to the requirements of IEC 61508.
Besides providing isolation, the PR 5202B is a barrier. This means that the module can make an intrinsically safe measurement of contacts and NAMUR sensors mounted in a zone 0/ Division 1 explosion hazard area. The PR 5202B limits the level of energy present at the contact or the NAMUR sensor to a low intrinsically safe level, thereby preventing ignition of a flammable atmosphere around the sensor – even if the sensor or the cable is damaged.