Teknik Belgeler
Özellikler
Controller Type
Detector
Ürün Tipi
Aydınlatma Kontrol Cihazı
Sensör Tipi
Cadmium Sulphide
Akım
10A
Gerilim
230 V
Montaj Tipi
Duvar
Dimmable
Yes
Time Delay
10 to 40 s
IP Değeri
IP54
Genişlik
70 mm
Yükseklik
51.5mm
Uzunluk
95mm
Güç
250mW
Standartlar/Onaylar
UL
Seri
V10524
Ürün Ayrıntıları
Adjustable 5-1000 Lux
Daylight Lighting Controllers
These controllers automatically turn lights 'ON' and 'OFF' in response to changes in ambient light levels, primarily the transition from day to night and vice-versa. The more advanced types (see note below) have inbuilt logic to minimise false triggering, whereas the remainder have inbuilt time delays or higher 'OFF' thresholds, to prevent on/off cycling. As a general rule, these controllers should be sited such that they are not illuminated, by the light they are controlling. Nominal supply voltage is 230Vac.,Note regarding energy-saving negative-hysteresis controllers,Where figures for the 'OFF' threshold are lower than for the 'ON' threshold, the sensor is designed such that four thresholds are actually monitored. These are: dusk, the middle of the night, dawn and the middle of the day. Monitoring at times other than dusk and dawn enables the sensor to determine what it should be looking for next, minimising false triggering and improving overall controller operation.
Stok bilgileri geçici olarak kullanılamıyor.
Teklif İsteyiniz
1

Teklif İsteyiniz
Stok bilgileri geçici olarak kullanılamıyor.
1

Teknik Belgeler
Özellikler
Controller Type
Detector
Ürün Tipi
Aydınlatma Kontrol Cihazı
Sensör Tipi
Cadmium Sulphide
Akım
10A
Gerilim
230 V
Montaj Tipi
Duvar
Dimmable
Yes
Time Delay
10 to 40 s
IP Değeri
IP54
Genişlik
70 mm
Yükseklik
51.5mm
Uzunluk
95mm
Güç
250mW
Standartlar/Onaylar
UL
Seri
V10524
Ürün Ayrıntıları
Adjustable 5-1000 Lux
Daylight Lighting Controllers
These controllers automatically turn lights 'ON' and 'OFF' in response to changes in ambient light levels, primarily the transition from day to night and vice-versa. The more advanced types (see note below) have inbuilt logic to minimise false triggering, whereas the remainder have inbuilt time delays or higher 'OFF' thresholds, to prevent on/off cycling. As a general rule, these controllers should be sited such that they are not illuminated, by the light they are controlling. Nominal supply voltage is 230Vac.,Note regarding energy-saving negative-hysteresis controllers,Where figures for the 'OFF' threshold are lower than for the 'ON' threshold, the sensor is designed such that four thresholds are actually monitored. These are: dusk, the middle of the night, dawn and the middle of the day. Monitoring at times other than dusk and dawn enables the sensor to determine what it should be looking for next, minimising false triggering and improving overall controller operation.