RS PRO, MAXX Surge Suppressor Unit 253V Maximum Voltage Rating 6.5 kA Maximum Surge Current EMC Filter

Teknik Belgeler
Özellikler
Marka
RS ProÜrün Tipi
Aşırı Gerilim Koruma Birimi
Bastırıcı Tipi
EMC Filter
Maksimum Gerilim
253V
Montaj Tipi
DIN Rayı
Maksimum Ani Akım
6.5kA
Seri
MAXX
Minimum Çalışma Sıcaklığı
-25°C
Maksimum Çalışma Sıcaklığı
85°C
Standartlar/Onaylar
ANSI/ESD S20.20:2014
Tehlikeli Alan Sertifikası
NO
Ürün Ayrıntıları
Surge & Noise Suppressor, MAxx / D Series
Combined surge and RFI filter units
Warning
Will not pass a 500V insulation test.
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.
Stok bilgileri geçici olarak kullanılamıyor.
Teklif İsteyiniz
1

Teklif İsteyiniz
Stok bilgileri geçici olarak kullanılamıyor.
1

Teknik Belgeler
Özellikler
Marka
RS ProÜrün Tipi
Aşırı Gerilim Koruma Birimi
Bastırıcı Tipi
EMC Filter
Maksimum Gerilim
253V
Montaj Tipi
DIN Rayı
Maksimum Ani Akım
6.5kA
Seri
MAXX
Minimum Çalışma Sıcaklığı
-25°C
Maksimum Çalışma Sıcaklığı
85°C
Standartlar/Onaylar
ANSI/ESD S20.20:2014
Tehlikeli Alan Sertifikası
NO
Ürün Ayrıntıları
Surge & Noise Suppressor, MAxx / D Series
Combined surge and RFI filter units
Warning
Will not pass a 500V insulation test.
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.